AKCP - DCS - Licence 5 dry contact for SP2+
Licence for SP2+ - 5 floating contacts (per port) (MAC ID of the SP2+ is required)
Listpris:
416,85 kr*
Pris för återförsäljare - Inloggning
1 stycken tillgängliga, leveranstid: 3 - 5 arbetsdagar
Tillverkarens artikelnummer:
DCS
Vårt artikelnummer:
940145
Frågor? Vi hjälper dig gärna! → Kontaktformulär
Produktinformation "AKCP - DCS - Licence 5 dry contact for SP2+"
5 Input Dry Contact license
These dry contact ports can be used to monitor any dry contact inputs through an RJ45 sensor port. Have up to 10 dry contacts on an SP2 and 20 on an SP2+. The sensor requires the 10 dry contact unlock license for the SP2. On the SP2+ 5 dry contact licenses are sold on a per-port basis. The dry contacts on the 5DCS are input only, if you require I/O on a sensor port, use the single dry contact cable (DCS15).
Suitable for:
These dry contact ports can be used to monitor any dry contact inputs through an RJ45 sensor port. Have up to 10 dry contacts on an SP2 and 20 on an SP2+. The sensor requires the 10 dry contact unlock license for the SP2. On the SP2+ 5 dry contact licenses are sold on a per-port basis. The dry contacts on the 5DCS are input only, if you require I/O on a sensor port, use the single dry contact cable (DCS15).
Suitable for:
- SP2+ Basic
- SP2+ Professional
- SP2+ Basic LCD
- SP2+ Professional LCD
Features
- SNMP interface for alarm/normal status.
- SNMP traps can be sent when the sensor is in a critical state.
- SNMP polling is possible via SNMPget.
- Web browser interface is available.
- When an alarm condition is activated the description and location of the fault can be sent via an email or SNMP trap.
Technical details
Measurement Range
Alarm or Normal
Sensor Type
Open / Closed contact switch (input only)
Contact voltage range
5 volts pulled-up dry contacts*
Measurement Rate
Multiple readings every second
Normal input state is settable under software
Interface
Communications Cable
RJ-45 jack to sensor using UTP Cat 5 wire
Communications Cable Max. length
1000 Ft (305m) with approved low capacitance shielded cable or UTP
Power Source
Powered by the controller unit. No additional power needed
Dimensions
56 x 55 x 33.3 mm
Mounting
DIN rail mounting
Screw mounting
Up to 5 dry contact inputs per RJ-45
– making up to 10 Dry Contact Inputs in sensorProbe2
– making up to 20 Dry Contact Inputs in sensorProbe2+
Important Note
Dry Contacts are not isolated, don’t connect any voltage source
Sensor count
5
Measurement Range
Alarm or Normal
Sensor Type
Open / Closed contact switch (input only)
Contact voltage range
5 volts pulled-up dry contacts*
Measurement Rate
Multiple readings every second
Normal input state is settable under software
Interface
Communications Cable
RJ-45 jack to sensor using UTP Cat 5 wire
Communications Cable Max. length
1000 Ft (305m) with approved low capacitance shielded cable or UTP
Power Source
Powered by the controller unit. No additional power needed
Dimensions
56 x 55 x 33.3 mm
Mounting
DIN rail mounting
Screw mounting
Up to 5 dry contact inputs per RJ-45
– making up to 10 Dry Contact Inputs in sensorProbe2
– making up to 20 Dry Contact Inputs in sensorProbe2+
Important Note
Dry Contacts are not isolated, don’t connect any voltage source
Sensor count
5