Växla till startsidan
Välkommen till S-CONNECT - Components for Solutions

AKCP - Battery Monitoring 500-600A CT

Battery Monitoring 500-600A CT
Listpris:

1 369,65 kr*

Leveranstid: För närvarande cirka 3-4 veckor

Icon
Priser för större kvantiteter på förfrågan.
Tel: +46 (0) 42-13 60 60 eller e-post: shop@s-connect.se
Tillverkarens artikelnummer: BAT-CT600
Frågor? Vi hjälper dig gärna! Kontaktformulär
Produktinformation "AKCP - Battery Monitoring 500-600A CT"
Battery Monitoring Sensor for monitoring the voltage, temperature, and current load for batteries and DC power systems.

The Battery Monitoring Sensor monitors an individual cell or bank of batteries, as well as DC power systems like solar panel arrays. With Battery Monitoring Sensor, you can monitor:
  • The temperature of the battery terminals
  • The voltage output from batteries or panel array
  • Current load on batteries or charging circuit
Typical applications would be for battery monitoring, solar panel array, or generator starter batteries.

Generator Battery
Place the Battery Monitoring Sensor on your generator starter battery. Monitor the crank current from the starter motor, battery voltage, and temperature, or monitor the alternator charge current, voltage, and battery temperature.
This can be used as a diagnostic tool to identify a battery that needs replacing or a problem with the alternator or starter motor.
For example, a decreasing crank current may be a sign that the battery although still having sufficient voltage does not have enough power output to crank the engine, resulting in a failure to start situation.

Solar Panel Array
Monitor the voltage and current output from your panels. Identify if they are running at less than optimum efficiency, for example, if they are dirty and need cleaning.

Battery Stack
The Battery Monitor system monitors the output of voltage and current from the battery stack, as well as battery temperatures.

Charge Status
By comparing the battery current load and the solar panel charging load you can identify if your system is providing sufficient charging power if you are draining your batteries, and if so at what rate they are being consumed.

Note: Correctly sized CT must be ordered with the BATTMON. CT value is set in production and can’t be changed!
Technical details

Measurements

Power Rating
Input Voltage and Current ratings:
Voltage: 0~60VDC (3 configurable ranges : 0~15V, 0~30V or 0~60V)
Current: DC current via external CT
+ 50A (standard)
+ 100A
+ 200A
+ 400A
+ 500A
+ 600A
+ 800A
+ 1000A
+ 1500A

Power Measurements
- Voltage (V): +/-0.05% Full-Scale, error +/-0.05% Full-Scale
- Current (A) : +/-0.05% Full-Scale, error +/-0.05% Full-Scale, Temperature Drift : +/-0.02%/°C
- Power (W) : +/-0.05% resolution

Environment monitoring
- Temperature sensor with 1 meter cable (*range -40°C to +75°C)

Status Indication
LED indication for power
LED indication for input presence

Inputs
1x sensor RJ45 Port
Hardwired with following plugs:
- Phoenix connector for voltage
- Phoenix connector for temperature
- Phoenix connector for external current transformer

Interface

Communications cable
RJ-45 jack to sensor using UTP CAT5e/6 cable

Power source
Powered by the sensorProbe+ familiy units. No additional power needed

Maximum Cable Length
Run length is 32 feet (10 meters) with approved low capacitance shielded cable or UTP

Dimensions
56 x 55 x 33.3 mm

Mounting
DIN rail mounting
Screw mounting

Components
Manufactured using highly integrated, low power surface mount technology to ensure long term reliability.

Operating Environment
Temperature: Min. -35° C – Max.80° C
Humidity: Min. 20% – Max. 80% (Non-Condensing)

MTBF
1,400,000 Hours based on field experience with sensorProbe units.

Sensor count
4

Important Note: the BattMon sensor is not galvanically isolated, care must be taken regarding possible differential voltage potential issues
sensorProbe+ units auto detects the presence of the ILPM sensor
- The BattMon sensor is only compatible with the sensorProbe+ platform units.
- When plugging the first time or after upgrading a sensorProbe+ unit, the sensor's firmware might be upgraded by the unit and not be available right away.
- On the sensorProbeX+, the sensor can be used only on the main module sensor ports